File No. A-0-56-6/2007-NIAH

National Institute of Animal Health

Department of Animal Husbandry, Dairying and Fisheries

Ministry of Agriculture

Government of India

Baghpat: Uttar Pradesh-250609

Phone- 0121-2222471-472, Fax-0121-2222291                                                 Dated- 24-09-2009

TENDER NOTICE

Closing date & time for receipt of Tenders                 21 October, 2009 at 2.30 P. M. (1430 Hours)

Tender opening date & Time                                      21 October, 2009 at 3.00 P. M. (1500 Hours)

Sealed tenders are invited from reputed firms/manufacturers/authorized agents for supply of the following equipment/machinery for National Institute of Animal Health, Baghpat:-

 

Item No.

Brief description of item

Type of item

Quantity

1.

Biosafety Cabinet Class II A2

Equipment

5 units

2.

Fume hood      

Equipment

2 units

3.

Refrigerated Microcentrifuge

Equipment

1 unit

4.

Circulating Water Bath

Equipment

1 unit

5.

Water Softener Plant   

Machinery

1 unit

6.

Freeze Dryer System                            -          

Equipment

1 unit

7.

Karl-Fischer Moisture Analyzer

Equipment

1 unit

 

2.         Tender documents, technical specifications of the required items are available on working days from the date of advertisement. Tender documents may also be downloaded from our website www.dahd.nic.in. Tender will not be accepted through electronic/online process.

3.         All bids must be accompanied by a Bid security specified in the Tender Document and must be delivered to the address mentioned in this letter on or before 1430 Hours (IST) on the date mentioned above. Bids will be opened in the presence of representative of bidders or authorized representatives who choose to attend in person on the above mentioned date and time.

4.         In the event of the specified date for the submission and opening of tenders being declared holiday for purchaser office, the due date for submission and opening of tenders will be the next working day at the appointed time.

5.         It is the responsibility of the bidders to ensure that their tender whether sent by post or by courier or in person are dropped in the tender box in the National Institute of Animal Health,

Department of Animal Husbandry, Dairying and Fisheries Ministry of Agriculture, Government of India, Baghpat, by closing date and time specified above for receipt of tender failing which tender would be considered late and rejected.

6.         Tender documents are not transferable.

 

 

 

Joint Director

 

TENDER DOCUMENT

 

 

 

 

NATIONAL INSTITTUE OF ANIMAL  HEALTH

Ministry of Agriculture

Department of Animal Husbandry, Dairying and Fisheries

Baghpat,-250609 (U.P.)

File No.                                                                                                                        24-09-2009

 

 

 

Sub: Tender for Supply of Laboratory Equipments  at National Institute of Animal Health, Baghpat

 

The National Institute of Animal Health (NIAH), Department of Animal Husbandry, Dairying and Fisheries, Ministry of Agriculture, Baghpat, intends to procure the following laboratory equipments:

1.      Biosafety Cabinet Class II A2                     -           Five units

2.      Fume hood                                     -           Two units

3.      Refrigerated Microcentrifuge                       -           One unit

4.      Circulating Water Bath                                -           One unit

5.      Water Softener Plant                                  -           One unit

6.      Freeze Dryer System                                  -           One unit

7.      Karl-Fischer Moisture Analyzer                  -           One unit

Quotations for supply and installation of the above listed equipments as per the requisite specifications on the terms and conditions at NIAH, Baghpat are invited.

1.         Item/s with specifications:     Enclosed (Page No. 1-8)

2.         Tenders

 

A.     Must be delivered, in the office of the Director, National Institute of Animal Health, Department of Animal Husbandry, Dairying & Fisheries, Ministry of Agriculture, Government of India, Baghpat, Uttar Pradesh-250 609 by 21st  October, 2009 latest by 1430 hrs (IST).

 

B.     Tenders must be written in English. All accompanying technical literature, and correspondence in connection with/or arising from a bid shall be in English.

 

C.     The firms should specifically quote the name of the manufacturer and model of the equipment quoted and clearly indicate the deviations from the required specifications, if any. Merely stating that the specification of the model quoted is as per the required specifications will render the tender to be treated as un-responsive.

 

D.     The tenderer should submit the technical brochure in original, conforming the claim of the specification as quoted in the tender. 

 

E.      The tenderer should submit, wherever possible, a user list for the model quoted only.

 

F.      Two-Bid System

 

The tender is to be submitted in two separate sealed envelopes labeled as under:  

1.         TECHNICAL–BID (Envelope No.1):

(a)        The tender document in original including the blank Price-Bid duly signed and stamped as a token of acceptance, along with deviation if any, from particular tender conditions in a separate sheet.

(b)        A crossed Demand  Draft for Rs 10000/-(Rs. Ten  thousand only) for each item quoted in favour of the Pay and Account Officer (Extension), Department of Agri. & Cooperation payable at NEW DELHI from any Nationalized Bank, as Earnest Money Deposit (EMD).

2.                  PRICE–BID (Envelope No:2):

(a)        The Price–Bid price bid duly signed and stamped by the bidders.

         The Envelopes No: 1 & 2 shall be sealed separately and should be placed in a third Envelope which also shall be sealed and duly superscripted as “TENDER FOR                                                 SUPPLY OF LABORATORY EQUIPMENTS  AT NATIONAL INSTITUTE OF ANIMAL HEALTH, BAGHPAT”.

 

            The Technical–Bid (Envelope No.1) shall be opened first. The Price-Bid (Envelope No.2) will be opened only of those tenderers whose Technical–Bid is found to be in order and for which they shall be intimated separately about date and time by fax/ telephone.

 

 

G.     The price of the item should be quoted in Indian rupees and in case any tenderer does not quote the price in the Indian rupees, the same will be treated as unresponsive.   Price quoted in foreign currency must have its conversion price in Indian Rupees, which only will be taken into consideration.

 

H.     Tenders must be addressed to:-

 

The Director,

National Institute of Animal Health,

                        Department of Animal Husbandry, Dairying & Fisheries,

                        Ministry of Agriculture,

                        Govt. of India

                        Baghpat, Uttar Pradesh-250 609

 

3.         Late Tenders

A.     Any tender received by the Purchaser after the deadline for submission of tender will be rejected and returned unopened to the Tenderer.

 

4.         Opening of Tender

 

A.     All Tenders will be opened in public on 21st October, 2009 at 1500 Hrs. in the Conference Room, National Institute of Animal Health, Department of Animal Husbandry, Dairying & Fisheries, Ministry of Agriculture, Government of India, Baghpat, Uttar Pradesh-250 609.  Tenderers or their representatives may be present during this meeting.

 

5.         Documents Establishing Tenderer’s Eligibility and Qualifications:

 

A.     The Tenderer shall furnish, as a part of its tender, documents establishing the Tenderer’s eligibility to tender and its qualification to perform the Contract if its tender is accepted.

 

B.     The documentary evidence of the Tenderer’s qualification to perform the contract if its tender is accepted shall establish to the Purchaser’s satisfaction:

 

i.         that the Tenderer has the financial, technical and production capability necessary to perform the Contract;

ii.       that the Tenderer meets the qualification criteria.

 

6.         Period of Validity of Tenders

 

A.     Validity of Tenders shall be 90 days after the date of tender opening.  A tender valid for a shorter period shall be rejected by the Purchaser as non-responsive.

 

B.     In exceptional circumstances, the Purchaser may solicit the Tenderer’s consent to an extension of the period of validity.  The request and the responses thereto shall be made in writing (or by cable).  A Tenderer granting the request will not be permitted to modify its tender.

 

 

7.         Evaluation and Comparison of Tenders

 

A.     The Purchaser will evaluate and compare the tenders, which have been determined to be substantially responsive.

 

B.     The Purchaser’s evaluation of a tender will exclude and not take into account:

 

i.         Sales and other similar taxes, which will be payable if a contract is awarded to the Tenderer;

 

ii.       The prices of recommended spare parts will not be taken into account for evaluation.

 

C.     The Purchaser’s evaluation of a Tender will take into account one or more of the following factors:

 

i.                     cost of inland transportation, insurance and other costs incidental to the delivery/installation of the system in the field offices,

 

ii.                   delivery schedule offered in the tender,

 

iii.                  deviations in payment schedule from that specified in the terms and conditions of contract,

 

iv.                 the projected operating and maintenance costs of the system,

 

v.                   the performance and productivity of the system offered; and/or

 

vi.                 other specific criteria indicated in the Technical Specifications.

 

8.         Award Criteria

 

A.     The purchaser will award the contract to the successful Tenderer whose tender has been determined to be substantially responsive and has been determined to be the lowest evaluated tender, provided further that the Tenderer is determined to be qualified to perform the contract satisfactorily.  However, if the specifications are not found as per the prescribed specifications, the claim of the lowest quotee will be ignored.

 

 

9.         Purchaser’s Right to vary Quantities at time of award

 

A.     The Purchaser reserves the right at the time of contract award to increase or decrease.  The quantity of goods and services originally specified in the Scheduled of Requirements without any charge in unit price or other terms and conditions.

 

10.       Purchaser’s Right to accept any Tender and to reject any or all Tenders

 

A.     The Purchaser reserves the right to accept or reject any tender, and to annual tender process and reject all tenders at any time prior to contract award, without thereby incurring any liability to the affected Tenderer or tenderers or any obligation to inform the affected Tenderer or tenderers of the grounds for the Purchaser’s action.

 

11.       Notification of award

 

A.     Prior to the expiration of the period of tender validity, the purchaser will notify the successful Tenderer in writing by registered letter or by cable, to be confirmed in writing by registered letter, that its tender has been accepted.

 

B.     The notification of award will constitute the formation of the contract.

 

C.     Upon the successful Tenderer’s furnishing of the contract the purchaser will promptly notify each unsuccessful Tenderer.

 

12.       Signing of Contract

 

A.     At the same time as the purchaser notifies the successful Tenderer that its tender has been accepted, the purchaser will send to the Tenderer the Contract Form provided in the tender documents, incorporating all agreements between the parties.

 

B.     Within thirty (30) days of receipt of the Contract Form the successful Tenderer shall sign and date the Contract and return it to the Purchaser.

 

13.       Standards

 

A.     The Systems/services provided under this contract shall conform to the standards mentioned in the Technical Specifications, and, when no applicable standard is mentioned, to the authoritative standard appropriate to the Deptt. of AHD&F and such standards shall be the latest issued by the concerned Institution.

 

14.       Delivery and Documents

 

A.     Delivery and installation of the system/services shall be made by the Supplier within 30 days from the date of placing order which may be extended at the discretion of the competent authority.

 

B.     Documents to be submitted by Supplier are specified in technical specifications.

 

15.       Transportation

 

A.     The transportation costs etc. to transport the equipment to the consignee’s place shall be born by the tenderer.

 

16.       Incidental Services

 

A.     The supplier may be required to provide any or all of the following services, including additional services, as specified in Technical Specifications:

 

a)                  Performance or supervision of on-site installation, etc. of the system.

 

b)                  Furnishing of tools required for assembly and/or maintenance of the System.

 

c)                  Furnishing of detailed operations and maintenance manual for each appropriate unit of system.

 

17.       Warranty

 

A.     The supplier warrants that the System and services provided under the contract are based on new, unused, latest, most recent or current models, and that they incorporate all recent improvements in design and materials unless provided otherwise in the contract.  The supplier further warrants that all services/systems supplied under this contract shall have no defect, arising from design, materials, or workmanship except when the design and/or material is required by the purchaser’s specifications) or from any act or omission of the Supplier, that may develop under normal use of the supplied system in the conditions prevailing in the Board.

 

B.     The stores shall carry standard guarantee/warrantee for a period of at least 12 months after final inspection from the date of successful commissioning and handing over to the consignee at site or 15 months from the date of supply.

 

C.     The purchaser shall promptly notify the supplier in writing of any claims arising under this warranty.

 

D.     Upon receipt of such notice, the supplier shall immediately repair or replace the defective system without any cost to the purchaser.

 

E.      If the supplier, having been notified, fails to remedy the defect (s) within a reasonable period, the Purchaser may proceed to take such remedial action as may be necessary, at the supplier’s risk and expense and without prejudice to any other rights which the purchaser may have against the supplier under the contract.

 

18.       Payment

 

A.     No advance payment shall be made.

 

B.     For tenders denominated in Indian Rupees, the payment shall be made through Cheque/Demand Draft by the Deptt. of AHD&F within 30 days only after the Provisional Acceptance Certificate (PAC) is received duly certified that the items has been received in good condition as per the specification and working satisfactorily.

 

19.       Change Orders

 

A.     The purchaser may at any time, by a written order given to the supplier make changes within the general scope of the contract in any one or more of the following:

 

i.         the place of delivery/installation; and/or

 

ii.       the services to be provided by the supplier,

 

iii.      the mode/method of despatch and packing.

 

B.     If any such change causes an increase or decrease in the cost of, or the time required for, the supplier’s performance of any provision under the contract, an equitable adjustment shall be made in the contract price or delivery schedule, or both, and the contract shall accordingly be amended.  Any claims by the supplier for adjustment under this clause must be asserted within thirty (30) days from the date of the supplier’s receipt of the purchaser’s order.

 

20.       Assignment

 

23.1          The supplier shall not assign, in whole or in part, its obligations to perform under this contract, except with the purchaser’s prior written consent.

 

21.       Subcontracts

23.1     The supplier shall notify the purchaser in writing of all subcontracts awarded under this contract, If not already specified in the tender.  Such notification, in the original tender or later, shall not relieve the supplier from any liability or obligation under the contract.

 

22.       Delays in the Supplier’s Performance

A.     Delivery of the equipment/performance of the services shall be made by the Supplier in accordance with the time schedule prescribed by the purchaser in the Schedule of Requirements.

 

B.     If at any time during performance of the contract, the supplier or its sub-contractor(s) should encounter conditions impeding timely delivery of the goods and performance of services, the supplier shall promptly notify the purchaser in writing of the fact of the delay, its likely duration and its cause(s).  As soon as practicable after receipt of the supplier’s notice, the purchaser shall evaluate the situation and may at its discretion extend the supplier’s time for performance, with or without liquidated damages, in which case the extension shall be ratified by amendment of the contract.

 

23.       Liquidated Damages

 

A.     If the supplier fails to deliver any of all of the goods or to perform the services within the period (s) specified in the contract, the purchaser shall, without prejudice to its other remedies under the contract, deduct from the contract price, as liquidated damages, a sum equivalent to 1% percent specified in contract or unperformed services for each week or part thereof delay until actual delivery or performance up to 5% maximum deduction of the percentage specified in Contract.  Once the maximum is reached, the purchaser may consider termination of the contract.

 

24.       Termination for Default

 

A.     The Purchaser, without prejudice to any other remedy for breach of contract, by written notice of default sent to the supplier, may terminate this contract in whole or in part:

 

i.         If the supplier fails to deliver any or all of the services/systems within the period(s) specified in the contract, or within any extension thereof granted by the purchaser; or

 

ii.       If the supplier fails to perform any other obligation(s) under the contract.

 

iii.      If the supplier, in the judgment of the purchaser has engaged in corrupt or fraudulent practices in competing for or in executing the contract.

 

B.     In the event the purchaser terminates the contract in whole or in part, the purchaser may procure, upon such terms and in such manner as it deems appropriate, goods or services similar to those undelivered, and the supplier shall be liable to the purchaser for any excess costs for such similar goods or services.  However, the supplier shall continue performance of the contract to the extent not terminated.

 

25.       Termination for Insolvency

 

A.     The purchaser may at any time terminate the contract by giving written notice to the supplier if the supplier becomes bankrupt or otherwise insolvent.  In this event, termination will be without compensation to the supplier, provided that such termination will not prejudice or affect any right of action or remedy which has accrued or will accrue thereafter to the purchaser.

 

 

26.       Termination for Convenience

 

A.     The purchaser, by written notice sent to the supplier, may terminate the contract, in whole or in part, at any time for its convenience.  The notice of termination shall specify that termination is for the purchaser’s convenience, the extent to which performance of the supplier under the contract is terminated, and the date upon which such termination becomes effective.

 

B.     The goods that are complete and ready for despatch within thirty (30) days after the supplier’s receipt of notice of termination shall be accepted by the purchaser at the contract terms and prices.  For the remaining goods, the purchaser may elect:

i.                     To have any portion completed and delivered at the contract terms and prices, and/or

 

ii.                   To cancel the remainder and pay to the supplier an agreed amount for partially completed goods/services and for materials and parts previously procured by the supplier.

 

27.       Resolution of Disputes

 

A.     The purchaser and the supplier shall make every effort to resolve amicably by direct informal negotiation any disagreement or dispute arising between them under or in connection with the contract.

 

B.     For resolution of disputes, appropriate legal action shall be initiated in consultation with the Department of Legal Affairs, Government of India.  Relevant sections of Indian laws as amended from time to time shall be applicable and binding on the tenderer.

 

28.       Taxes and Duties

 

A.     The supplier shall be entirely responsible for all taxes, duties, license fees, etc. incurred until completion of the contract.

 

29.          Clarification of Tenders and Contacting the Purchaser for clarification of Tenders

 

A.     During evaluation of the tenders, the Purchaser may at its discretion, ask the Tenderer for clarification of its tender.  The request for clarification and the response shall be in writing and no change in the prices or substance of the tender shall be sought, offered or permitted.

 

B.     No Tenderer shall contact the Purchaser on any matter relating to its tender from the time of the tender opening to the time the contract is awarded.  If the Tenderer wishes to bring additional information to the notice of the Purchaser, it should do so in writing.

 

C.     Any effort by the Tenderer to influence the Purchaser in the Purchaser’s tender evaluation, tender comparison or contract award decisions may result in the rejection of the Tenderer’s offer.

 

 

30.       Preliminary Examination

 

A.     The Purchaser will examine the tenders to determine whether any computational errors have been made, whether required sureties have been furnished, whether the documents have been properly signed, and whether the tenders are generally in order.

 

B.     Arithmetical errors will be rectified on the following basis.  If there is a discrepancy between unit prices and the total price and quantity, the unit price shall prevail and the total price shall be corrected.  If the supplier does not accept the correction of errors, its tender will be rejected, and its Earnest Money will be forfeited.  If there is a discrepancy between words and figures, the amount in words will prevail.

 

C.     The Purchaser may waive any minor informality, nonconformity, or irregularity in a tender which does not constitute a material deviation, provided same does not prejudice or affect the relative ranking of any Tenderer.

 

D.     Prior to the detailed evaluation, the Purchaser will determine the substantial responsiveness of each tender to the Tender Documents without material deviations.

 

E.      If the tender is not substantially responsive, it will be rejected by the Purchaser and may not subsequently be made responsive by the Tenderer by correction of the non-conformity.

 

F.      The tenderer should submit the technical brochure in original, conforming the claim of the specification as quoted in the tender.  In case the specifications given in the Brochure do not tally with the specification quoted, the tender shall be treated as un-responsive.

 

G.     The tenderer should also enclose the list and addresses of Service Centers.

 

31.       Packaging-marking

 

A.     For all items, supplies shall be packaged in such a way that they are protected from all damage during transport (whether by sea, air, road or rail).   Each outer package will be indelibly and legibly marked.

 

B.     A packing list showing the contents of the package must be kept inside each and every package.

 

C.     All packing materials shall become the property of the National Institute of Animal Health, Baghpat.

 

32.       Places of destination and delivery period

 

A.     The constitution and destination of the different components of each lot will be as indicated in the Equipment Distribution Annex.

 

B.     The delivery period shall be stated by the bidder in his offer, but should not be more than two months from the date of receipt of the letter of contract.  Delivery periods outside this limit will be taken into consideration during evaluation of bids.

 

33.       Acceptance

A.     For all items acceptance, both provisional and final will be by the Director, National Institute of Animal Health, Department of Animal Husbandry, Dairying & Fisheries, Ministry of Agriculture, Government of India, Baghpat, Uttar Pradesh-250 609 or his authorized representatives after unpacking all the supplies comprising a particular lot at their various final destinations. 

 

Director

National Institute of Animal Health

 

 

Annexure-I

TERMS AND CONDITIONS

A.        Despatch Instruction

1.  Stores as detailed above to be supplied to the respective consignee F.O.R. DESTINATION basis and no packing, forwarding, freight charges etc. will be paid extra by the institute

2.  Shortage, pilferage in transit will be sole responsibility of the supplier and same will be intimated to the supplier on receipt of goods by the purchaser to make good the loss caused on this account. The defective supply will be replaced by the supplier within 7 days without freight /transport charge

3.  Supply should be made in full against the order and shortage will be procured on the risk and cost the supplier

4.  The articles should be securely packed to avoid damages etc. in transit.

B.        INSPECTION:

The item(s) will be subject to the inspection/approval by consignee(s)/actual user(s) and their decision will be FINAL. However, in case the stores supplied are not found according to the specifications given, you will remove the rejected items from the premises of the consignee. The institute will not take any responsibility for the rejected stores.

C.        PAYMENT

1. Pre-receipted bill, in triplicate, for the value of items will have to be submitted to this office along with the valid receipt. Payment shall be made by Demand Draft/crossed cheque in favour of the name of Company/agencies. Request for advance payment will not be entertained

2. No payment will be made for unsatisfactory supply

D.             The Director, NIAH reserves the right to reject any or all the terms and condition of contract at any time without assigning any reasons thereof.

E.             The decision of the Director, NIAH shall be the final

 

 

TECHNICAL SPECIFICATIONS OF MACHINERY AND EQUIPMENTS

 

 

Biological Safety Cabinet (Class II- Type A2)

 

·        Biological Safety Cabinet should be of 70% recirculation and 30% exhaust type (Class II type A2), Microprocessor controlled, designed to discharge HEPA-filtered exhaust air directly into the laboratory.

·        Cabinet dimension should be 1250 mm W x 875 mm D x 1560 mm H (54” x 31” x 61”) approximately.

·        The exterior of cabinet should be epoxy coated steel.

·        The Cabinet interior should be of radiused type 304 SS and leak tight 18 gauge SS work surface with reduced corner.

·        The work surface and front intake grille should be single piece and should be removable.

·        A drain trough should be available beneath the work tray which should have drain valve.

·        Work area should have fluorescent light mounted in uncontaminated area to provide 80 to 150 foot candles on work area.

·        Front side shutter should have 100 tilt angled sash with approx. 30” of viewing height.

·        Fully closing clear Sash made of tempered safety glass, uv intercepting and have audible and visible alarm for sash exceeding safety height.

·        Cabinet should have air negative pressure channel.

·        Should have Motor Blower assembly for regulated air intake and exhaust.

·         Cabinet should have lab cocks for gas and air, service fixture, electrical outlets with cover on each wall.

·         HEPA filter 99.99% efficient on all particles 0.3 µm or larger in entry and exit level of air flow.

·        Cabinet should have nominal down flow velocity of 55 fpm (0.3 m/sec) and nominal inflow velocity - 105 fpm (0.5m/sec) and should have class 5 condition as per ISO 14644-1 and 2 (formerly class 100) in the work area.

·        Airflow motor and air filter should be easily serviceable from front/sides of cabinet.

·        Should have digital display of life span of filter with real time alarm for filter change. The system should be capable to increase speed automatically to compensate filter loading.

·        Air exhaust, velocity of air laminar flow in m/s, should be displayed.

·         Biological Safety Cabinet must have alarm for low air exhaust, low air flow velocity and exhaust fan fault.

·        In case of malfunction with the exhaust fan, the blower should stop working automatically.

·        The blower should be capable to remain on idle when sash is fully closed.

·        The Biological Safety Cabinet should be NSF 49 certified, Air cleanliness ISO14664, electrical safety standards for 230Vv and 50Hz.

·        Should be provided with telescoping base stand suitable to provide working height from 30” to 36’. Stand should be of tubular SS with casters.

·        Should have minimum Three year warranty.

·        Voltage stabilizer, if required, should be supplied alongwith.

 

Circulatory Waterbath

·        Working Temperature Range -100 to 2000 C.

·        Temperature Controller: Fully Microprocessor Based

·         Multifunctional , digital display and alarm

·        Temperature Accuracy/Stability:±0.020C

·        Uniformity of The Temperature in Bath:0.10  C

·        Outer Body: 16 S.W.G., C.R.C. Sheet, Duly Powder-Coated or in stainless-Steel.

·        Interior should be made of Mirror Polished 304/316 Grade Stainless-Steel.

·        Bath Filling Volume: 3-4 Ltr. Inner Chamber should be rounded.

·        Heater Capacity: 1200W,  Automatic/Supplementary Heater Cutoff.

·        Refrigerant: should conform to CFC free.

·        Pump Flow Rate: 5 Ltr/Min.

·        Temperature sensor (External or Internal probe).

·        Adjustable: High Temperature Cut-Off, Over Temperature Protection

·        Dry Run Protection System, Over Load and Over Heat Protection.

·        Delay time and Pressure Safety Switch to protect the compressor from excess pressure.

·        Refrigeration on/off control through relay.

·        Low Noise Level.

·        Lift up Bath Cover Variable, Made of Mirror Polished 302/316 Grade Stainless-Steel.

·        Insulation with Poly-Urethane foam to avoid heat/temperature loss.

·        Hermetically sealed Compressor with overheat protection system.

·        Air Cooled condenser.

·        Adjustable Nozzle Made of SS 304/316 Grade for Inlet & Outlet with suitable Silicon Rubber Tubing for liquid circulation.

·        Tap to drain out the liquid, from the inner chamber, complete part made of 304/316 Grade SS.

·        Supply complete along with 2 nos leads, to operate the equipment.

·        Input power Supply: 220-230 Volts,. 50Hz..

 

FREEZE DRY SYSTEM WITH ACCESSORIES

 

·        All in one freeze dry system in which Pre-freezing on the tray, Freeze Drying and Automatic Stoppering of Vials can be done in a single machine.

·        Bench top model with approximate overall dimensions of 70-75 cm x 70-75 cm x 70-75 cm (w x d x h).

·        It should accommodate approximately 350 to 180 serum bottles/vials of 2 to 10 ml capacity.

·        The Freeze Dryer System must also offer inbuilt neoprene valves for freeze drying in flasks apart from tray drying.

·        Tray / Shelf temperature should be in the range of -55° C to +50° C.

·        Stainless steel collector coil condenser capable of holding 2.5 liters of ice before defrosting.

·        CFC-free refrigeration system to cool collector to -80°C.

·        Probe for monitoring sample temperature.

·        System must allow Pre-freezing up to -75°C

·        Inbuilt Pneumatic stoppering mechanism

·        There should be memory to store at least five programs.

·        Moisture sensor to prevent vacuum start up when moisture is detected in the collector chamber area.

·        Vacuum control valve to maintain set point vacuum level.

·        Hot gas defrosts of collector chamber.

·        LCD to display operating parameters, set-up parameters and alarm messages.

·        Alarm system ( Audible  and visual ) for Power failure, Improper line voltage supply, if collector temperature rise above –40° C, for vacuum pump service, for moisture in collector and Alarm indicator for self temperature variation more than ±2° C. 

·        System should come with necessary software & hardware to transmit the data & get the data for representation.

·        Electrical requirement of the system should be : 230V, 50Hz ,12.0 A

·         Vacuum Pump: - Rotary Vane vacuum pump (oil pump) with minimum displacement capacity of 100 L/min or more and approximate ultimate vacuum/partial pressure in the range of 1.2 x 10-4 to 1.4 x 10-4 mBar. Must be two stage, oil sealed. Pump must include vacuum oil (extra one liter, exhaust filter, oil filter, odor filter and all necessary tubing’s.

Accessories:

1.     Vials borosilicate glass, aluminum seal finish, without closure, autoclavable of 2ml, 5ml and 10ml capacity.

                        2 ml    -    5000 Nos

                        5ml     -    5000 Nos

                        10 ml  -    2000 Nos

2.     Stoppers for 13mm and 20mm aluminum seal finish, gray butyl rubber, lypholization style.

                   13 mm    -    5000 Nos

                        20 mm     -   7000 Nos

3.     Aluminum seals for 13mm O.D and 20 mm O.D capacity one piece unlined tear out style.

                         13 mm    -    5000 Nos

                        20 mm     -   7000 Nos

4.     Hand operated crimpers to crimp 13mm and 20mm O.D capacity Aluminum seals on vials.

                        13 mm    -    One

                        20 mm     -   One

 

FUME HOOD

·        Nominal width of the fume hood should be 4 feet.

·        Chemical resistant, fiberglass-reinforced, composite panel liner and pre-set rear down flow dual baffle system with flame speed less that 25 per ASTM E-64.

·        Tempered safety glass, vertical-rising sash with handle.

·        Removable front and side panels and front and interior service access panels for access to plumbing and electrical wiring.

·        Sash stop should be located at 18” sash opening position.

·        Epoxy-coated stainless steel, 12.81”ID exhaust connection(s).

·        The front and side panels should be easily removable for lamp replacement and access to electrical supply connection

·        Maximum height of sash should be 28” for superior viewing. When fully open, the sash should not extend above the hood.

·        With regard to safety, the offered fume hood should have conformity to the International regulations and standards, viz: NFPA 45-2004, ASTM E84-01, ASHRAE 110-95, ANSIZ 9.5-2003, UL 1805, CE CONFORMITY MARKING

·        Installation will include the assembly of remote blower, necessary duct work, suitable work surface and stand. Successful installation will mean the rendering of the fume hood in working condition.

·        The provided work surface should be molded from a formulation of corrosion-resistant epoxy resins. It should conform to the interior liner of the offered fume hood.

·         The fume hood should have provision to be connected to outside of the room in which it is installed. 

 

Refrigerated Micro Centrifuge

·        Microprocessor controlled

·        Automatic lid lock

·        Automatic imbalance detection

·        Maintenance free brushless motor

·        Maximum Rotational speed: 16,000 /min (approx.)

·        Maximum Centrifugal Force: 25,000 x g (approx)

·        Temperature Range :  -8 Deg C to +40 Deg C

·        Have fast cool function: from room temperature to 4 0 C in approx. 15 min

·        RPM or RCF settings in steps of 100 rpm

·        Short spin function with preselected rotational speed

·        The Refrigerated Centrifuge should maintain a sample temperature of 4 0

C, even at maximum speed.

·        Should have embossed foil keypad for simple operation, soft key for gentle acceleration and deceleration

·        Digital display for speed, RCF, RPM, running time, temperature.

·        Timer upto 99 min or continuous run

·        System should have a minimum thick PUF (Polyurethane foam) insulation for better heat insulation and delayed temperature rise in the event of power failure

·        Rotors, rotor lids, and adapters should be  autoclavable (20 min, 1210 C)

·        Power Supply: 230 V 50Hz

·        Fixed angle rotor - 24 x 1.5/2ml including aluminum lid,

·        Aerosol-tight

·        Constant Voltage Stabilizer (142-275 V)

 

Karl-Fischer Moisture Analyser

 

·        Based on Coulometric Karl Fischer titration method

·        Dual platinum electrode

·        With stirrer pump, cylinder

·        Motor driven 3/2 way valve

·        Titration stand and vessel with integrated magnetic stirrer

·        Titration vessel should be hermetically sealed to prevent moisture penetration

·        High-contrast LCD display

·        Equipment should be programmed for sample titration, titre water, titre liquid standard and  blank values.

·        For measuring sample 100 ppm to 100%

·        Automatic drift correction on start up

·        Should generate mean, standard deviation and relative standard ddeviation

·        Result output in terms of %, ppm, mg, mg/l, mg/pc, ml

·        PC compatible

 

Water Softener Plant

·        Semi-automatic reverse osmosis based DM water processing unit

·        Capacity- 900L per hour.

·        Site of installation- NIAH, Baghpat.

·        Required parameter of processed water at system outlet

 

     Parameter              Prov. Raw Water            Required Parameter

TDS                      -        ≤ 650 mg/l                       ≤ 50 ppm

     pH                        -        7-8                                  6.0 ± 0.5

     Total hardness                -        ≤ 300 ppm                      ≤ 10 ppm    

 

It is assumed that the raw water will have TDS- ≤ 650 mg/l, pH- 7-8, Hardness- ≤300 ppm, alkalinity- ≤250 ppm, Sulphate- ≤50 mg/l, Chloride- ≤150 mg/l, Silica- ≤21 mg/l, CoD- ≤5 and BoD- ≤ 1mg/l.

 

The unit should consist of-

 

1.        Raw water booster pump:

·        To boost water pressure from raw water tank and deliver to pretreatment at pressure and volume required.

·        SS 304 Pump of Grundfoss or equivalent

2.        Pre-treatment Unit

·        Sediment filter unit

·        Activated carbon unit

·        Anti-scalant dosing unit

·        Micron filtration unit- 10µand 5µ

 

3.     Membrane Block

·        RO module (housing and Membrane) with controls and instrumentation and auto flushing cum CIP unit

4.           Water buffer storage tank

5.     Transfer pump with hydro-pneumatic

Necessary pipe and fittings

The interconnecting piping for the water treatment system along with valves and other fittings shall be in SS 304.

Miscellaneous Items / Instruments required -  

 

Pressure Gauge, Flow Indicator, Conductivity Indicator, pH Indicator, Pressure Switch, Control Panel with Cabling, Level Switches.